VorTech Battery Back-Up - EcoTech Marine

VorTech Battery Back-Up - EcoTech Marine

$249.99
Sale price  $249.99 Regular price  $249.99
Skip to product information
VorTech Battery Back-Up - EcoTech Marine

VorTech Battery Back-Up - EcoTech Marine

$249.99
Sale price  $249.99 Regular price  $249.99

Order Protection

Reef Guard Eligible

Fast Delivery

Packed With Care

Expert Support

We've got your back!

Goes well with:

Description
The VorTech Battery Back-Up from EcoTech Marine provides seamless power continuity for VorTech MP-series pumps during outages, keeping flow running for up to 36 hours with an MP40w or up to 72 hours with an MP10 or MP20. The unit houses an 18 Amp-Hour 12-volt sealed battery in a powder-coated aluminum enclosure and ships with all necessary wiring and a trickle charger. Two units can be daisy-chained to double runtime. It is also compatible with EcoTech Vectra return pumps when used with the separately sold Vectra Battery Booster Cable. A straightforward, purpose-built solution for reef keepers who already run EcoTech flow equipment.

A power outage becomes a livestock problem when circulation stops. The supplied EcoTech Marine information warns that fish and corals can begin to die within four to ten hours in an aquarium with no flow. The VorTech Battery Back-Up is designed to preserve that flow automatically when normal power is interrupted. Rather than attempting to operate every device on the aquarium, it supports compatible EcoTech pumps so water continues moving through the outage. For an aquarist already using VorTech equipment, this creates a focused backup plan centered on maintaining circulation during the period when the main electrical supply is unavailable.

The unit contains an 18 Amp-Hour, 12-volt sealed battery inside a powder-coated white aluminum housing. It connects to compatible pump equipment and remains supported by the included trickle charger between outages. When mains power is lost, the backup is intended to activate automatically rather than waiting for someone to discover the outage and connect emergency equipment. That automatic transition is particularly relevant when the aquarium is unattended. The system does not require a whole-aquarium backup configuration to keep a supported circulation pump operating, although the supplied information does not claim that it powers unrelated aquarium devices.

The specifically identified VorTech pumps are the MP10, MP20, and MP40w. Model choice matters because the published maximum runtime is not the same across those pumps. The supplied specifications list up to 72 hours for an MP10 or MP20 on one Battery Back-Up and up to 36 hours for an MP40w. These model-specific figures are more useful for planning than treating the product as if it had one universal runtime. Aquarists using a VorTech model not expressly named in the supplied record should verify compatibility separately rather than assuming that every pump carrying the VorTech name has the same connection or runtime.

EcoTech publishes model-specific maximum estimates of up to 72 hours for the MP10 and MP20, up to 36 hours for the MP40w, and up to 30 hours when supporting two pumps. Treat these as manufacturer estimates rather than fixed promises. The supplied information does not provide one standardized runtime or a detailed test method for every pump arrangement.

The runtime variables documented in the supplied information are the connected pump model, whether one or two pumps are being supported, and whether one or two Battery Back-Up units are used. An MP40w has a lower stated maximum runtime than an MP10 or MP20. A two-pump configuration is listed at up to 30 hours from one unit. Connecting a second Battery Back-Up is stated to double the available runtime. The record does not quantify the effects of battery age, operating settings, or environmental conditions, so an aquarist should not assign unsupported adjustments to the published figures when planning outage coverage.

It is important to distinguish adding a second pump from adding a second battery. Supporting two pumps increases the electrical load, and EcoTech lists up to 30 hours for that arrangement with one Battery Back-Up. Connecting another Battery Back-Up increases stored capacity, with the supplied information stating that two units provide twice the runtime. This modular approach lets an EcoTech-based circulation plan be expanded without changing the basic backup format. However, the record does not provide a complete table covering every combination of pump models, pump quantities, and paired batteries, so mixed or more complex installations require additional confirmation.

The Battery Back-Up can also be used with EcoTech Vectra return pumps, but a Vectra installation has an additional requirement: the EcoTech Vectra Battery Booster Cable. That cable is required for operation and is sold separately. The statement that all necessary wiring cables are included therefore applies to the standard VorTech package, not to a Vectra conversion. The supplied record does not identify individual Vectra models or publish a Vectra runtime. Aquarists planning to preserve return-pump circulation should confirm their specific Vectra configuration and obtain the Booster Cable rather than expecting the included VorTech wiring alone to complete the connection.

For outage planning, the principal function is continued water movement. That circulation is relevant when the normal pumps have stopped and the aquarium is entering the four-to-ten-hour no-flow window identified in the product information. The Battery Back-Up should consequently be evaluated by which supported pump will remain active and where that pump normally moves water. The source does not provide a measured oxygenation rate or promise that every area of an aquarium will receive identical circulation. It also does not provide livestock-specific survival times beyond the general warning about fish and corals in a system without flow.

Physical planning is straightforward because the enclosure dimensions are supplied. The Battery Back-Up measures 9 inches long by 7 inches wide by 3.25 inches high, equivalent to 228 by 177 by 82.5 millimeters. Its sealed 12-volt battery is housed in powder-coated white aluminum. These dimensions should be checked against the intended equipment area before installation, especially if a second unit may later be added to double runtime. The source does not state a required mounting orientation, clearance, or environmental rating, so those details should not be assumed from the aluminum construction alone.

The complete package includes the Battery Back-Up, an integrated 18 Amp-Hour sealed battery, a trickle charger, and the wiring cables needed for the standard VorTech application. The charger is intended to keep the battery charged between outages so the backup remains prepared. No separately sourced wiring is described as necessary for the named VorTech pumps. Vectra users are the exception because their setup requires the separately sold Battery Booster Cable. The supplied record does not list replacement battery components, mounting hardware, monitoring accessories, or a Vectra Booster Cable as included package contents.

A cautious functional test should be limited to confirming the behavior the product is designed to provide. With the Battery Back-Up connected, charged through its trickle charger, and wired to a compatible pump, briefly interrupt normal power to that pump and observe whether circulation continues from battery power. Restore normal power after confirming the transition. The supplied information does not provide a manufacturer test interval, a prescribed full-discharge procedure, or a target measured runtime for periodic testing. For that reason, a brief controlled check is more directly supported than deliberately exhausting the battery merely to reproduce the maximum advertised duration.

Battery care centers on the included trickle charger. Its stated purpose is to maintain charge so the system is ready when an outage occurs. A controlled activation check can also reveal whether the pump changes to backup operation, but a short check cannot prove that an aging unit will still reach its original maximum runtime. EcoTech does not provide a replacement interval, expected service life, capacity threshold, or user replacement procedure in the supplied record. Replacement timing therefore cannot be determined from a calendar date on this information alone, and the published runtime figures should not be treated as a permanent measurement of battery condition.

This model is best suited to an outage plan built around the specifically named VorTech pumps or a compatible Vectra installation equipped with the required Booster Cable. Its main planning advantages are automatic activation, model-specific published runtime guidance, an included maintenance charger, and the ability to link a second battery for twice the runtime. The important limitations are equally clear: maximum duration varies by configuration, Vectra runtime is not stated, the Booster Cable is not included, and no battery replacement schedule is supplied. Those boundaries allow an experienced aquarist to choose coverage without assuming support, duration, or maintenance requirements that EcoTech has not documented here.

Overview

Flow When Power Fails

The VorTech Battery Back-Up keeps your EcoTech pumps running through outages — automatically, without manual intervention.

  • Extended Runtime

    • Up to 72 hours on MP10 and MP20 pumps
    • Up to 36 hours on the MP40w
    • Chain two units together to double runtime
  • Ready Out of the Box

    • Includes trickle charger to maintain battery charge between outages
    • All wiring cables included — no additional hardware required
    • Activates automatically when mains power is lost
  • Versatile Compatibility

    • Compatible with VorTech MP10, MP20, and MP40w pumps
    • Works with EcoTech Vectra return pumps (Booster Cable sold separately)
    • 18 Amp-Hour 12V sealed battery in aluminum housing

Features

  • Complete Package, Ready to Install

    Complete Package, Ready to Install

    The retail package includes the battery back-up unit, trickle charger, and all wiring cables needed for connection to a VorTech pump driver. No supplementary hardware purchases are required for MP-series pump installations.

  • Rear Panel Ports and Wiring

    Rear Panel Ports and Wiring

    The rear panel exposes 12VDC output ports and labeled wiring connection points, supporting direct driver hookup and daisy-chain expansion to a second Battery Back-Up unit for doubled runtime.

Specifications

VORTECH BATTERY BACK-UP

Battery
18 Amp-Hour, 12V sealed
Housing
Powder-coated white aluminum
Dimensions (L x W x H)
9" x 7" x 3.25" (228mm x 177mm x 82.5mm)
Runtime — MP10 / MP20
Up to 72 hours (single unit)
Runtime — MP40w
Up to 36 hours (single unit)
Runtime — Two pumps
Up to 30 hours (single unit)
Charger
Trickle charger included
Vectra Compatibility
Requires EcoTech Vectra Battery Booster Cable (sold separately)
Compatible VorTech Pumps
MP10, MP20, MP40 and MP60 families with battery-backup port
Included Accessories
Trickle charger and pump connection wiring
Expandable Runtime
Connect a second Battery Backup to approximately double runtime
Product Type
12V aquarium circulation-pump backup battery

Expert buying guidance

VorTech Battery Back-Up FAQs

How long does the EcoTech VorTech Battery Backup last?

EcoTech publishes model-specific maximum estimates of up to 72 hours for an MP10 or MP20, up to 36 hours for an MP40w, and up to 30 hours when supporting two pumps. These are manufacturer estimates, not guaranteed runtime. Battery age and condition, pump model, operating mode, and the connected setup can reduce actual runtime. A second Battery Back-Up may extend runtime. Verify current EcoTech documentation for your exact pump and driver before relying on a duration.

Which VorTech pumps work with the EcoTech Battery Backup?

The supplied record specifically identifies the EcoTech VorTech MP10, MP20, and MP40w. It lists up to 72 hours of backup for the MP10 and MP20 and up to 36 hours for the MP40w from one unit. Although the description also refers more broadly to VorTech MP-series pumps, it does not name every VorTech generation or model. If your pump is not one of the three specifically listed, do not infer compatibility or the same runtime from this record alone; verify the exact pump and driver configuration separately.

Can the EcoTech Battery Backup run a Vectra return pump?

Yes, the supplied information states that the Battery Back-Up is compatible with EcoTech Vectra return pumps, but operation requires the EcoTech Vectra Battery Booster Cable. That cable is sold separately and should be treated as a required part of the Vectra installation, even though standard VorTech wiring is included with the backup. The record does not identify individual Vectra models or provide a Vectra-specific runtime estimate. Confirm the exact Vectra configuration before relying on it for return-pump coverage, and do not apply the published MP10, MP20, or MP40w runtime figures to a Vectra.

What is included with the VorTech Battery Back-Up?

The package includes the Battery Back-Up with an 18 Amp-Hour, 12-volt sealed battery housed in a powder-coated white aluminum enclosure. A trickle charger is included to maintain charge between outages, along with the wiring cables needed for the standard VorTech application. The enclosure measures 9 by 7 by 3.25 inches, or 228 by 177 by 82.5 millimeters. A Vectra Battery Booster Cable is not included; it is separately sold and required when connecting the backup to an EcoTech Vectra return pump.

How do I test an aquarium battery backup safely?

The source does not provide a formal EcoTech testing procedure or test interval. A cautious functional check is to connect the charged Battery Back-Up and included wiring to a compatible pump, briefly interrupt that pump’s normal power, and observe whether circulation continues from the battery. Restore normal power once the automatic transition is confirmed. Keep the included trickle charger in use between outages so the battery remains prepared. The supplied information does not call for routine full-discharge testing, and a short activation check cannot confirm that the battery will still achieve the published maximum runtime.

When should an EcoTech Battery Backup battery be replaced?

The supplied record does not state a replacement interval, expected battery lifespan, minimum capacity threshold, or replacement procedure. It therefore does not support replacing the sealed battery after a specific number of months or years. Use the included trickle charger to maintain charge between outages and perform controlled functional checks to confirm that the connected pump transfers to backup operation. Bear in mind that a brief activation test verifies the transition but not the full available runtime. If replacement timing must be established, it cannot be determined from the published information provided here.

Related items

Ships FREE with Livestock

View all
Clean Up Crew Invertebrate Pack – Algae Control

Clean Up Crew Invertebrate Pack – Algae Control

Clean Up Crew Invertebrate Pack – Algae Control

$34.99
Sale price  $34.99 Regular price  $33.88
Clean Up Crew Invertebrate Pack – Sand Cleaners

Clean Up Crew Invertebrate Pack – Sand Cleaners

Clean Up Crew Invertebrate Pack – Sand Cleaners

$44.99
Sale price  $44.99 Regular price 
Clean Up Crew Invertebrate Pack – Full Arsenal

Clean Up Crew Invertebrate Pack – Full Arsenal

Clean Up Crew Invertebrate Pack – Full Arsenal

$79.99
Sale price  $79.99 Regular price  $85.83
Nassarius Snail

Nassarius Snail

Nassarius Snail

$3.99
Sale price  $3.99 Regular price 
Skunk Cleaner Shrimp

Skunk Cleaner Shrimp

Skunk Cleaner Shrimp

$42.49
Sale price  $42.49 Regular price  $42.49
Tiger Sand Conch

Tiger Sand Conch

Tiger Sand Conch

$14.99
Sale price  $14.99 Regular price 
Astrea Snail

Astrea Snail

Astrea Snail

$2.49
Sale price  $2.49 Regular price 
Emerald Crab

Emerald Crab

Emerald Crab

$7.99
Sale price  $7.99 Regular price 

Ships FREE with Corals

View all
Green Seaweed - Premium Nori - Reef Genetics

Green Seaweed - Premium Nori - Reef Genetics

Green Seaweed - Premium Nori - Reef Genetics

$8.99
Sale price  $8.99 Regular price 
Reef Glue - Reef Genetics

Reef Glue - Reef Genetics

Reef Glue - Reef Genetics

$2.99
Sale price  $2.99 Regular price 
Chemi-Pure Blue - Boyd Enterprises

Chemi-Pure Blue - Boyd Enterprises

Chemi-Pure Blue - Boyd Enterprises

$2.95
Sale price  $2.95 Regular price  $2.95
Chemi-Pure Elite - Boyd Enterprises

Chemi-Pure Elite - Boyd Enterprises

Chemi-Pure Elite - Boyd Enterprises

$10.89
Sale price  $10.89 Regular price  $10.89
Reefer Madness UV Reactive T-Shirt

Reefer Madness UV Reactive T-Shirt

Reefer Madness UV Reactive T-Shirt

$34.99
Sale price  $34.99 Regular price 
TSA Mini Logo Hat

TSA Mini Logo Hat

TSA Mini Logo Hat

$34.99
Sale price  $34.99 Regular price 
Zesty Bites (Sour Candy) - Zesty Snacks

Zesty Bites (Sour Candy) - Zesty Snacks

Zesty Bites (Sour Candy) - Zesty Snacks

$6.99
Sale price  $6.99 Regular price 
Command Bus Cable - Hydros

Command Bus Cable - Hydros

Command Bus Cable - Hydros

$7.50
Sale price  $7.50 Regular price