Versa Pump 4 Pack with Base Station - EcoTech Marine

Versa Pump 4 Pack with Base Station - EcoTech Marine

$849.99
Skip to product information
Versa Pump 4 Pack with Base Station - EcoTech Marine

Versa Pump 4 Pack with Base Station - EcoTech Marine

$849.99

UPC: 653341192028

Goes well with:

90 Day Returns

Reef Guard Covered

Ships Overnight

Orders Over $399*

Expert Support

We've got your back!

Price Match Guarantee We match verified competitor prices.
Looking for something specific? Tell us what you need.
Description
The Versa Pump 4 Pack with Base Station bundles four of EcoTech Marine's precision peristaltic pumps with a dedicated rail-style Base Station and consolidated power supply. Each Versa pump uses a DC stepper motor with planetary gearing to deliver an exceptionally wide dosing range — from 0.5 µL to 300 mL per minute — making the system suitable for everything from trace element dosing to automated water changes and ATO. Control is handled entirely through EcoTech's Mobius app, which supports up to 30 discrete dosing points, three dosing modes, and integration with other Mobius-connected equipment. The Base Station keeps all four pumps organized on a single 12.8" rail and provides a single consolidated power connection. This package suits hobbyists who want a scalable, app-controlled dosing platform without the clutter of independent pump setups.

The EcoTech Marine Versa Pump 4 Pack with Base Station is a coordinated four-channel peristaltic system for aquarists who already know they need several controlled fluid-handling points. The package includes four Versa pumps, the four-position Base Station, and a consolidated power supply. That configuration can support multi-part additive dosing, automatic water changes, auto top off, reactor feeding, or a mixture of those jobs. Its main distinction from purchasing unrelated pumps is organization: all four Versas occupy one 12.80-inch rail and share the Base Station’s power arrangement while retaining the wide operating range and Mobius programming available to each pump.

Four channels are especially useful when the dosing plan extends beyond a simple two-part regimen. An aquarist could reserve separate pumps for multiple supplements, dedicate channels to the removal and addition sides of an automated water-change layout, or combine routine dosing with ATO or reactor-feed duties. The package does not require all four pumps to perform the same task. Before installation, assign each channel a specific role and determine where its source container, discharge point, and tubing run will be located. Planning those routes first helps take advantage of the Base Station’s compact organization rather than creating a difficult-to-service bundle of crossed lines.

The Base Station measures 12.80 inches long by 1.51 inches wide by 3.52 inches high and provides four docking spaces. Each Versa pump measures 3.15 inches long by 2.34 inches wide by 3.45 inches high. The listed input voltage is 110V, and the package’s consolidated supply powers the pumps through the Base Station instead of requiring a separate supply arrangement for every position. When selecting a mounting location, account for the rail dimensions, all four pump bodies, tubing bends, and access needed for future tubing service. The source describes quiet operation, but placement should still prioritize dry, accessible equipment space rather than relying on sound level alone.

Each Versa has a stated dosing range from 0.5 microliters per minute to 300 milliliters per minute. That span allows the same pump design to address very small additive quantities as well as higher-volume ATO and water-change movement. Listed accuracy is plus or minus 0.2 mL for quantities below 1 mL and plus or minus 2% from 1 to 300 mL. Those specifications should guide channel selection and programming, but they do not eliminate the need to calibrate the installed pump. Actual installations include tubing routes, head height, connections, and serviced pump tubing, so programming should be based on the completed physical layout rather than an assumed output.

Programming and calibration are performed through EcoTech Marine’s Mobius app, which is available for Android and iOS devices and communicates through onboard Bluetooth Low Energy connectivity. Mobius offers automated, continuous, and manual dosing modes, along with as many as 30 discrete dosing points. This gives the four-pack flexibility to handle both repeated small additions and applications that run for longer periods. The system can also integrate with other EcoTech equipment operating through Mobius, including responses associated with feed mode. EcoTech states that a Mobius system can support more than 200 Versa pumps, so this four-pump station can remain part of a larger Versa installation.

Calibration is important because the source identifies Mobius calibration as part of normal Versa setup, but EcoTech does not provide a fixed recalibration interval in the supplied information. Avoid treating an unsupported weekly, monthly, or annual schedule as a product requirement. Establish each pump through the app after its final tubing layout is installed, and use a measured-volume check whenever the channel’s delivered amount needs confirmation. Tubing service or a meaningful routing change is also a sensible point to verify output before returning a critical dosing channel to unattended operation. Keep channel identities clear so a calibration or programming change is applied to the intended pump.

The pump connections accept 1/4-inch outside-diameter push-connect tubing, including 1/4-inch RO tubing. A 1/4-inch stem-to-barb adapter can also be used when the installation calls for soft tubing. This makes tubing selection straightforward, but the four-channel layout still requires careful organization. Keep each intake and discharge line identifiable from container to destination, avoid routing that makes one channel easy to mistake for another, and leave enough access to inspect connections and replace the pump tubing. The package’s explicit included-items list names the four pumps, Base Station, and power supply, so confirm any application-specific tubing, adapters, containers, or mounting supplies needed for the planned installation.

Automated water changes are an expressly supported Versa application. A typical four-pump allocation can dedicate one channel to removing aquarium water and another to adding prepared replacement water, leaving two pumps available for dosing or another supported use. Because the supplied information does not state that the package measures salinity, reservoir volume, or sump level, those conditions should not be assumed to be monitored by the Versa itself. Carefully verify the programmed movement of both water-change channels, keep their tubing paths distinct, and consider how catch-up behavior and other schedules fit the installation before enabling unattended operation. The listed 18-foot vertical head-pressure capability per pump can help with equipment-room routing, but every channel should still be calibrated in its actual route.

The same broad flow range also makes the four-pack relevant when one equipment cabinet contains several different fluid-handling tasks. Fine additive dosing can operate alongside larger-volume ATO movement or reactor feeding without changing to a different pump platform. Continuous-use applications are part of the stated design intent, and the Versa uses a DC stepper motor with a planetary gearing mechanism. The construction is described as heavy-duty, with user-replaceable pump tubing. Even so, channel priorities matter: a high-volume water-transfer line, a trace-dose line, and a reactor-feed line have different consequences if they are assigned incorrectly or connected to the wrong reservoir.

Mobius includes safeguards against overdosing and user error as well as catch-up functionality. These controls are useful when building a multi-channel schedule, but the source does not define every safeguard condition or justify treating software as a substitute for installation checks. Review dose amounts, units, operating mode, dosing points, and channel identity before activating a program. Catch-up settings deserve particular attention on water-change, ATO, and concentrated-additive channels because a delayed action may not have the same practical consequence in every application. Integration with another Mobius device, such as feed mode, should likewise be configured according to the assigned job of each Versa rather than applied uniformly to all four pumps.

Routine maintenance is centered on keeping the peristaltic tubing and fluid connections serviceable. EcoTech describes the tubing as tough, easily replaceable, and intended to provide longevity with minor service effort. Mount the Base Station where all four pump heads can be reached without dismantling surrounding equipment, and arrange lines so servicing one channel does not pull on another channel’s fittings. Inspect the tubing path and push-connect points as part of normal equipment care, especially where a line carries additives or operates continuously. After service, confirm that the intake still reaches the correct source, the discharge reaches the intended destination, and the programmed pump corresponds to that physical line.

Choose this four-pack when four planned channels, a single organized rail, and consolidated power are more useful than adding pumps individually over time. It is particularly logical for a complete multi-part dosing installation, an automatic water-change pair combined with two other functions, or a cabinet where four Versa pumps are already part of the design. Individual pumps may be the more measured choice when only one channel is currently needed or when there is no clear use for all four docking positions. The package carries EcoTech Marine’s listed one-year parts-and-labor warranty. Its strongest practical value is not simply owning more pumps, but deploying four clearly assigned, calibrated, and maintainable channels on one Mobius-controlled platform.

Overview

Dose. Automate. Scale.

Four Versa peristaltic pumps on a single Base Station — built for precision dosing across the full range of reef keeping applications.

  • Wide-Range Flow Control

    • Dosing range from 0.5 µL to 300 mL per minute
    • Handles trace dosing, ATO, water changes, and reactor feeding
    • Accuracy rated at ±2% across the 1–300 mL range
  • Mobius App Control

    • Programs via Mobius app on Android or iOS — no PC required
    • Three dosing modes: automated, continuous, and manual
    • Up to 30 discrete dosing points with overdose safeguards
    • Integrates with other Mobius equipment, including feed mode
  • Organized Base Station

    • Rail mounts up to four Versa pumps in a single footprint
    • Consolidated power supply reduces wall adapter clutter
    • Scalable platform supports over 200 Versa pumps per system

Inside the Versa Pump 4 Pack with Base Station - EcoTech Marine

Versa Pump 4 Pack with Base Station
Versa Pump 4 Pack with Base Station

Four Versa peristaltic pumps mounted on the EcoTech Base Station rail

  • Includes 4x Versa Peristaltic Dosing Pump and Versa Base Station
  • Base Station dimensions: 12.80"L × 1.51"W × 3.52"H
  • Base Station input voltage: 110V; accepts up to 4 pumps
  • Each pump: 3.15"L × 2.34"W × 3.45"H, 110V input
  • Pump flow range: 0.5 µL/min to 300 mL/min
  • 18 ft vertical head pressure per pump
Versa Pump Accessory Kit
Versa Pump Accessory Kit

Tubing, fittings, and accessories for Versa pump installation

  • Includes tubing and connection hardware for pump setup
  • Compatible with 1/4" OD push-connect RO tubing
  • Accepts 1/4" stem-to-barb adapter for soft tubing applications
  • Replacement tubing is user-serviceable for ongoing maintenance
Power Supply
Power Supply

Consolidated power supply for the Versa Base Station

  • Single power supply feeds all four pumps via the Base Station
  • 110V input voltage
  • Eliminates need for individual pump power adapters

What's Included

  • Versa Pump 4 Pack with Base Station

    Versa Pump 4 Pack with Base Station

    Four Versa peristaltic pumps mounted on the EcoTech Base Station rail

  • Versa Pump Accessory Kit

    Versa Pump Accessory Kit

    Tubing, fittings, and accessories for Versa pump installation

  • Power Supply

    Power Supply

    Consolidated power supply for the Versa Base Station

Specifications

BASE STATION

Dimensions
12.80"L × 1.51"W × 3.52"H
Input Voltage
110V
Docking Spaces
4

VERSA PUMP

Min Dosing Volume
0.5 µL/min
Max Dosing Volume
300 mL/min
Accuracy
±0.2 mL for < 1 mL; ±2% for 1–300 mL
Dimensions
3.15"L × 2.34"W × 3.45"H
Input Voltage
110V
Vertical Head Pressure
18 ft
Tubing Connections
1/4" OD push connect (RO tubing); accepts 1/4" stem × barb adapter for soft tubing
Connectivity
Bluetooth Low Energy (BLE) via Mobius app
Warranty
1 year parts and labor (EcoTech Marine)